1-24 strings (optional) 120A (optional) multi-string protective plate test instrument
1.The HTE24C120 multi-function protection board testing system is mainly used to test whether various functional indexes of the power battery protection board are within the parameter range, thus providing a set of testing standards for staff. It is mainly used for testing power battery protection boards of manufacturers of protection boards and power battery manufacturers. The test functions include: overcharge protection voltage, overcharge recovery voltage, overdischarge protection voltage, overdischarge recovery voltage, overdischarge current protection, short-term protection performance test, charging current protection, balanced start-up voltage, balanced real-time current, total self-consumption current of protection plate, and single self-consumption current.
2. short circuit protection test (refers to the real short circuit protection test microseconds).
3. Single-section consumable test (refers to the cell current consumed by each protection plate)
4. Balanced current and balanced voltage (can accurately capture balanced current and balanced voltage).
5. Structural dimensions The instrument itself has a volume of 800 *600*1300mm and a net weight of 55KG.
6. Working environment The operating power supply requires mains AC220V input, power supply fluctuation range (170-260V), and operating environment temperature-10 C. At 40°C, the working humidity is between 10% and 90%. The maximum power of 600W only occurs under the condition of testing large current.
7. High Current Module Current levels are 60A, 120A and current accuracy is 0.1A
8. Voltage Module The voltage range is 0-5V, the programmable output is 0-5V, and the voltage precision is 5mV.
9. short circuit module Super capacitor, which completely simulates pack battery voltage, instantly short-circuits the protection plate, accurately capturing the short-circuit time and current.
Specific parameter standard
item parameter | Test range | accuracy |
Test the number of battery cells | Sections 1-24 are optional | |
voltage reference | Ternary lithium battery (3.8V), Ferric phosphate (3.0V) | |
Overcharge protection voltage | 0-5V | ±5mV |
Overcharge protection voltage | 0-5V | ±5mV |
Overcharge recovery voltage (self-recovery) | 0-5V | ±5mV |
Overdischarge recovery voltage (self-recovery) | 0-5V | ±5mV |
Overcharge protection current | 0-50A | ±0.1A |
Overdischarge protection current | 0-120A(可选) | ±0.1A |
Equalizing on voltage | 0-5V | ±5mV |
Equalizing real-time current | 0-1000MA | ±1mA |
Overcurrent protection delay | 0-15S | ±1mS |
Overcharge protection delay | 0-20S | ±1mS |
Overdischarge protection delay | 0-20S | ±1mS |
Total self-power consumption | 0-10MA | ±5uA |
Single-section self-power consumption | 0-500uA | ±1uA |
Internal resistance of loop | 0-500mΩ | ±1mΩ |
Short circuit protection (above 10 battery cells) | 0-9999us | ±1uS |
Scope of application | All hardware scheme protection boards and most software boards in the market | |
Note | 1. The ordinary version of the equipment can have 24 batteries, and if it is higher than 24 batteries, it can be customized. 2. The common version of the equipment has 60A and 120A overcurrent, which can be customized if large current is required. 3. Special test items are required and can be customized. |